2 PRISMÒ Separators mounted on a common manifold (one counter-current, or co-current), 200 psig max.Experimental Conditions1 Porter Mass Flowmeter Model 112
2 Teledyne Oxygen Analyzers
1 3D Instruments Pressure Gauge, 0-150 psig
1 0-100 psia Omega pressure transducer
Labtech Notebook Data Acquisition Software
Pentium PC running Windows 95 with Labtech Notebook Pro Windows based data acquisition software using a Metrabyte DAS-8 analog to digital data acquisition board.
Compare the performance of separator number in co-current flow with the same separator in counter-current flow at various pressures and flow rates. For one of these arrangements, determine the time necessary to approach steady state at the different pressures and flow rates.
Laboratory Worksheet
- permeate stream oxygen content- non-permeate stream oxygen content
- inlet pressure
- non-permeate flow rate
- total flow rate, from material balance
- time for steady-states
Previous | Next | Back to Main | Table of Contents