Pump: Oberdorfer Model 109 MB, 30 gpm at 30 ft. of head (water)
Rotameters: air, model 1A3555, SCFM of air at 8.1 psig, 70° F
CO2, model 1A35555, SCFM at 14.7 psia, 70° F
water, model 1A3555, 100% = 21.6 gpm at specific gravity = 1.0
NOTE: Procedures for correcting the rotameter reading for conditions different than the calibration conditions are given on the reference link [click here].
Tank: stainless steel, nominal 200 gallon capacity
Gas Analyzer:
HP 5890 Gas Chromatograph with thermal conductivity detector and integrator
Packing Heights: 5.5 ft. each section
Packing: top section -- structured packing, flexipac type
bottom section -- dumped packing, 5/8 polypropylene flexirings
The raw data and worksheets should at least contain the following information:
- differential pressure for top-middle and middle-bottom
- temperature of entering gas and liquid
- top, bottom and middle CO2 gas concentration
- air, CO2, water rotameter readings
- air, CO2 water flow rates, Vg, L, G.
- properties of water and gas
- number of moles transferred
- mole fraction of CO2 in the outlet water
- equilibrium liquid mole fractions of CO2
- D Xlm
- KLa, 1/KLa, Sc, Sc 1/2, (L/ m), (L/m ).72
-![]()
Previous | Next | Back to main | Table of Contents